Test Description
Number(s) below refer to the step number(s) on the
Diagnostic Chart:
2. Verifies that the fault is present.
3. If Diagnostic Trouble Code P0112 can be repeated
only by duplicating the Failure Records condition,
refer to the Temperature vs. Resistance Value table.
The table may be used to test the IAT sensor at
various temperatures to evaluate the possibility of
a "shifted" sensor that may be stored above or
below a certain temperature. If this is the case,
replace the IAT sensor. If the IAT sensor appears
to be OK, the fault is intermittent; refer to
Diagnostic Aids.
Intake Air Temperature Sensor
°C
Temperature vs. Resistance Values (approximate)
100
80
60
45
35
25
15
5
–5
–15
–30
–40
RODEO X22SE 2.2L ENGINE DRIVEABILITY AND EMISSION
°F
OHMS
212
177
176
332
140
667
113
1188
95
1802
77
2796
59
4450
41
7280
23
12300
5
21450
–22
52700
–40
100700