< Previous Next >
2011 - RX-8 - HVAC
AIR INTAKE ACTUATOR INSPECTION [MANUAL AIR CONDITIONER]
1. Connect battery positive voltage to air intake actuator terminal G, and ground to terminal C
(or A), and then verify that the air intake actuator operates as shown in the table.
If the operation condition is not normal, replace the air intake actuator.
Terminal
Air intake actuator operation
G
A
C
B+ Ground
-
B+
-
Ground
RECIRCULATE→FRESH
FRESH→RECIRCULATE