Mazda RX-8 Workshop Manual page 2849

2011 - rx-8
Hide thumbs Also See for RX-8:
Table of Contents

Advertisement

Connect the driver and passenger–side side air bag
module connectors.
Connect the passenger–side air bag module connector.
Connect the clock spring connector.
Inspect the voltage for PID/DATA monitor IGN_V_2
item using M-MDS.
Is the voltage of at least one terminal 9 V or more?
INSPECT WIRING HARNESS BETWEEN BATTERY AND FUSE
7
BLOCK
Connect the negative battery cable.
Switch the ignition to on.
Measure the voltage at instrument cluster connector
terminal 1G.
Is the voltage 9 V or more?
VERIFY THAT SAS CONTROL MODULE CONNECTOR TERMINAL
8
1X IS GROUND
Inspect the wiring harness between SAS control
module connector terminal 1X and ground for the
following:
Is the wiring harness normal?
CONFIRM THAT MALFUNCTION SYMPTOMS DO NOT RECUR
9
AFTER REPAIR
Switch the ignition to off.
Disconnect the negative battery cable and wait for 1
min or more.
Connect all disconnected SAS system connectors
during diagnosis.
Connect the driver and passenger-side
pre-tensioner seat belt connectors.
Connect the driver and passenger–side curtain air bag
module connectors.
Connect the driver and passenger–side side air bag
module connectors.
Short to power supply
Open circuit
YesGo to the next step.
No Repair the wiring
harnesses, then go to
Step 9.
YesReplace the SAS control
module, then go to the
next step.
(See
SAS CONTROL
MODULE
REMOVAL/INSTALLATION)
No Replace the wiring
harnesses, then go to the
next step.
YesComplete troubleshooting,
then explain repairs to
customer.
No Recheck malfunction
symptoms, then repeat
from Step 1 if malfunction
recurs.