Measure the A/C amplifier
terminal 2D voltage when
the temperature control
dials are set to MAX COLD
and MAX HOT by control
panel.
Are voltages are normal?
21 VERIFY THAT MALFUNCTION SYMPTOM
DOES NOT OCCURS AFTER REPAIR
If the refrigerant
discharged during
inspection has not been
recharged, discharge and
charge with new
refrigerant to the specified
level.
Does cool air blow out?
(Are results of refrigerant
system performance test
normal?)
< Previous Next >
© 2010 Mazda North American Operations, U.S.A.
No
Inspect the air mix link, air mix
crank, and air mix rod of the A/C unit
correctly and securely installed to
their positions.
(See
A/C UNIT
DISASSEMBLY/ASSEMBLY.)
Repair or install correctly for suspect
part according to inspection result,
then go to the next step.
YesTroubleshooting completed. Explain repairs to
customer.
No Recheck malfunction symptoms, then repeat from
Step 1 if malfunction recurs.