2011 - RX-8 - HVAC
CONDENSER REMOVAL/INSTALLATION
1. Disconnect the negative battery cable.
2. Discharge the refrigerant from the system. (See
3. Remove the aerodynamic under cover. (See
REMOVAL/INSTALLATION.)
4. Do not allow remaining compressor oil in the condenser and pipes to spill, and remove in the
order indicated in the table.
CAUTION:
If moisture or foreign material enters the refrigeration cycle, cooling ability will
be lowered and abnormal noise or other malfunction could occur. Always plug
open fittings immediately after removing any refrigeration cycle parts.
1Cooler hose (HI)
REFRIGERANT
CHARGING.)
AERODYNAMIC UNDER COVER