Tv Timing; Tv Output Timing; Figure 7-50: Ntsc Video Timing - Epson S1D13506 Technical Manual

Color lcd/crt/tv controller
Table of Contents

Advertisement

Epson Research and Development
Vancouver Design Center

7.6 TV Timing

7.6.1 TV Output Timing

Register Programming:
Vertical Non-Display Period = 20
VRTC Start Position = 0
TV VRTC Start Position (field 1)
TV VRTC Start Position (field 2)
Hardware Functional Specification
Issue Date: 02/03/26
The overall NTSC and PAL video timing is shown in Figure 7-50: and Figure 7-51: respec-
tively.
1
261
262
pre-equalizing
Field 1
pulse interval
261
262
263
Field 2

Figure 7-50: NTSC Video Timing

vertical blanking interval = 20 lines
2
3
4
5
6
7
vertical sync
post-equalizing
pulse interval
pulse interval
start of field 1
VNDP
1
2
3
4
5
6
start of field 2
VNDP
Start of Vertical Sync
8
9
10
19
20
7
8
9
10
19
Page 119
21
20
21
S1D13506
X25B-A-001-12

Advertisement