C. Characteristics; Cpu Interface Timing; Generic Timing; Figure 7-1: Generic Timing - Epson S1D13506 Technical Manual

Color lcd/crt/tv controller
Table of Contents

Advertisement

Page 48
7 A.C. Characteristics

7.1 CPU Interface Timing

7.1.1 Generic Timing

CLK
A[20:1]
M/R#
CS#
RD0#,RD1#
WE0#,WE1#
WAIT#
D[15:0](write)
D[15:0](read)
S1D13506
X25B-A-001-12
Conditions:
V
= 3.0V ± 10% and V
DD
T
= -40° C to 85° C
A
T
and T
rise
C
= 50pF (CPU Interface), unless noted
L
C
= 100pF (LCD Panel Interface)
L
C
= 10pF (Display Memory Interface)
L
C
= 10pF (CRT Interface)
L
T
t2
t3
CLK
t4
t7
t11

Figure 7-1: Generic Timing

Note
The above timing diagram is not applicable if MD12 = 1 (BUSCLK divided by 2).
= 5.0V ± 10%
DD
for all inputs must be < 5 ns (10% ~ 90%)
fall
t9
Epson Research and Development
Vancouver Design Center
t5
t6
t8
t10
t13
t12
Hardware Functional Specification
Issue Date: 02/03/26