FIPS
Table 74: Physical and logical interfaces on the G250-DCP front panel (continued)
Physical
Quantity
interface
ETH WAN
1
CCA
1
Analog Line
2
Analog
4
Trunk
CONSOLE
1
580 Administration for the Avaya G250 and Avaya G350 Media Gateways
Description
RJ-45 Ethernet LAN
switch port
RJ-45 port for
ACS (308) contact
closure adjunct box
Analog telephone ports
on the integrated
analog media module
Analog telephone ports
on the integrated
analog media module
Console port for direct
connection of CLI
console.
RJ-45 connector.
FIPS 140-2 logical
interface
Data input
●
Data output
●
Status output
●
Control input
●
Power output
●
Analog phones
●
Data input
●
Data output
●
Power input
●
Analog phone
●
trunks
Data input
●
Data output
●
Power input
●
Control inputs
●
Status output
●
Comments
Supports wide area
network connectivity
Contact Closure Adjunct.
Powers two contact-
closure relays.
Line 2 ceases to be a data
input/output from the
module and is directly
connected to Analog
Trunk, providing a power
interface when an
emergency state occurs:
Power failure
●
Failure to
●
communicate with a
call controller
Firmware error state
●
The Trunk ceases to be a
data input/output from the
module and is directly
connected to Analog
Line 2, providing a power
interface when an
emergency state occurs:
Power failure
●
Failure to
●
communicate with a
call controller
Firmware error state
●
Supports cryptographic
module administration
2 of 3