Avaya G250 Administration page 135

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Table 15: Trunk group data to assemble for SLS (continued)
*
Page
Field Name
2
Incoming
Calling Number
- Format
1
Incoming
Destination
1
Trunk Hunt
6
Sig Grp
* Page numbers might vary for your system.
Collecting DS1 trunks data
1. At the SAT, type display ds1 location and press Enter to display the DS1
administration for a particular circuit pack location.
2. Gather DS1 information according to
Table 16: DS1 circuit pack data to assemble for SLS
*
Page
Field Name
1
Name
1
Bit-Rate
1
Signaling Mode
1
Channel
Numbering
1
Connect
1
Interface
Notes
Specifies how to fill the Calling Party Number and Called
Party Number IEs
Sets a destination station for routing incoming trunk group
calls
Determines the method in which the
survivable-call-engine selects an available trunk from the
trunk group pool.
Specifies the Signaling Group Number that is the
manager of this ISDN trunk member.
Table 16
for each DS1 facility.
Notes
Descriptive name often of the Service Provider or
destination of the DS1 facility
Selects the maximum transmission rate of the DS1 facility
Selects the signaling method deployed on the given DS1
facility
E1 interface for ETSI and QSIG require sequential
encoding from 1 to 30.
This field appears when
Signaling Mode = isdn-pri
Bit Rate = 2.048
Connect = pbx
Specifies what is connected at the far-end of the DS1
facility
Determines glare handling
Configuring SLS
3 of 3
1 of 2
Issue 3 February 2007
135

Advertisement

Table of Contents
loading

This manual is also suitable for:

G350