Avaya G250 Administration page 162

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Configuring Standard Local Survivability (SLS)
The maximum limits for a given trunk type are defined by the built-in ports on the G250
family members and are defined by the slot-configuration assignment for the G350. The
maximum number of ports allowed per interface module is defined in
G250 and
Table 29: G250 SLS trunk group capacities
G250 model
G250
G250-BRI
G250-DCP
G250-DS1
Table 30: G350 SLS group type assignments
Group type
loop-start
ground-start
did
loop-start
loop-start
ground-start
did
did
bri
162 Administration for the Avaya G250 and Avaya G350 Media Gateways
Table 30
for the G350.
Mode
ISDN-T1
ISDN-E1
T1-Robbed Bit
E1-CAS
Media module
Number of
ports/channels
1
2
MM711
8
MM714
4
MM714
4
MM716
24
MM720
16
Number of
Description of maximum trunk
channels
group usage
4 analog loop-start trunk groups
2 analog DID trunk groups
4 BRI trunks (channels) total
1 analog loop-start trunk group
2 analog DID trunk groups
4 analog loop-start trunk groups
2 analog DID trunk groups
23
30
1 analog loop-start trunk group
24
2 analog DID trunk groups
30
Description of trunks that may be
assigned
V701
V702, V703
Ports 5, 6, 7, 8
Ports 1, 2, 3, 4
Eight physical ports, each offering B1
and B2 channels
Table 29
for the