Contact Closure Software Configuration - Avaya G250 Administration

Media gateways
Hide thumbs Also See for G250:
Table of Contents

Advertisement

Configuring contact closure

Contact closure software configuration

You can specify the following contact closure modes:
Mode
mgc
manual-trigger
manual-off
To configure the Avaya G250/G350 Media Gateway to activate contact closure when the feature
access code is dialed:
1. Enter the set contact-closure admin command. In the following example, the
command sets contact closure to work in relay 1 of the Avaya Partner Contact Closure
Adjunct when activated by the call controller.
set contact-closure admin 10/1:1 mgc
2. Use the set contact-closure pulse-duration command to set the length of time
for the relay to return to normal after the call controller triggers it. In the following example,
the command sets relay 2 of the Avaya Partner Contact Closure Adjunct to return to
normal 5 seconds after the call controller triggers contact closure in the relay.
set contact-closure pulse-duration 10/1:2 5
To activate contact closure manually, use the set contact-closure admin command with
the parameter manual-trigger. In the following example, the command activates contact
closure in relay 1 of the Avaya Partner Contact Closure Adjunct. Contact closure remains active
until you deactivate it by using the set contact-closure admin command with the
parameter manual-off or mgc.
set contact-closure admin 10/1:1 manual-trigger
To deactivate contact closure manually, use the set contact-closure admin command
with the parameter manual-off. In the following example, the command deactivates contact
closure in relay 2 of the Avaya Partner Contact Closure Adjunct. Contact closure will not
operate, even automatically, until you use the set contact-closure admin command to
change the status of contact closure to mgc or manual-trigger.
set contact-closure admin 10/1:2 manual-off
302 Administration for the Avaya G250 and Avaya G350 Media Gateways
Description
The MGC controls contact closure. In mgc mode, the
user dials feature access codes to activate and
deactivate contact closure.
Activates contact closure for the specified relay.
Deactivates contact closure for the specified relay.