Configuring Standard Local Survivability (SLS)
Example
add port V304 administers an analog loop-start trunk through port V304 on either
the G250-Analog or the G250-DCP.
Example
add port v401 adds a BRI trunk for the first physical port of the G250-BRI to a trunk
group using one B-channel of the BRI link.
Note:
You cannot mix BRI and PRI trunks within the same trunk group. If you attempt to
Note:
assign more than the maximum number of trunks to a trunk group, an error
message instructs you to delete a trunk member before adding a new trunk. A
physical trunk can be a member of only one trunk group.
5. For an analog DID trunk group, type set supervision sup-type to set the incoming
signaling supervision mode. sup-type can be either immediate or wink.
Example
set supervision wink assigns wink-start incoming signaling supervision to a DID
trunk group.
6. For a non-ISDN digital trunk (t1-inband or e1-inband), type set supervision
sup-type to set the incoming signaling supervision mode, where sup-type can be any
of the following:
loop-start
ground-start
wink-wink
wink-immediate
wink-auto
immediate-immediate
auto-auto
auto-wink
7. For an analog DID trunk group or DS1 tie trunk group, type set digit-treatment
digit-treat, where digit-treat is any of the following values:
blank (use this value to prevent any absorb or insert digit treatment from being
applied)
absorb1
absorb2
absorb3
absorb4
absorb5
166 Administration for the Avaya G250 and Avaya G350 Media Gateways