Configuring Standard Local Survivability (SLS)
Example
add port V304 administers an analog loop-start trunk through port V304 on either
●
the G250-Analog or the G250-DCP.
Example
add port v401 adds a BRI trunk for the first physical port of the G250-BRI to a trunk
●
group using one B-channel of the BRI link.
Note:
You cannot mix BRI and PRI trunks within the same trunk group. If you attempt to
Note:
assign more than the maximum number of trunks to a trunk group, an error
message instructs you to delete a trunk member before adding a new trunk. A
physical trunk can be a member of only one trunk group.
5. For an analog DID trunk group, type set supervision sup-type to set the incoming
signaling supervision mode. sup-type can be either immediate or wink.
Example
set supervision wink assigns wink-start incoming signaling supervision to a DID
●
trunk group.
6. For a non-ISDN digital trunk (t1-inband or e1-inband), type set supervision
sup-type to set the incoming signaling supervision mode, where sup-type can be any
of the following:
loop-start
●
ground-start
●
wink-wink
●
wink-immediate
●
wink-auto
●
immediate-immediate
●
auto-auto
●
auto-wink
●
7. For an analog DID trunk group or DS1 tie trunk group, type set digit-treatment
digit-treat, where digit-treat is any of the following values:
blank (use this value to prevent any absorb or insert digit treatment from being
●
applied)
absorb1
●
absorb2
●
absorb3
●
absorb4
●
absorb5
●
166 Administration for the Avaya G250 and Avaya G350 Media Gateways