Important:
Since you can administer your system for SLS either from the SAT or from the
Important:
gateway CLI, the two administration tasks must be synchronized with common
data and port usage as well as system-defined capacities. For example, if a
physical DCP station port number 10 is not administered on the Communication
Manager server, even though the gateway's SLS engine has that port
administered, the port is unusable during SLS operation on the gateway. This is
because the hardware port configuration on the media modules is initially
configured by CM in subtending gateway mode, by using the H.248 control
channel to push information down to the gateway.
SLS capacities
The following table lists the SLS capacities by gateway model:
Gateway
model
G250-Analog
G250-DCP
G250-BRI
G250-DS1
*
G350
* 72 stations maximum (all types)
You can collect the Communication Manager data using the CM administrative SAT interface.
For instructions on accessing the Avaya Communication Manager through the G250/G350, see
Accessing the registered MGC
Collecting analog stations data
1. At the SAT, type list media-gateway and press Enter to display a list of administered
gateways.
IP
Analog
stations
stations
12
2
12
2
12
2
12
2
72
The maximum number of legacy stations/trunks that may
be supported is dependent upon the slot-module
configuration of what is installed.
on page 76.
DCP
Analog
stations
trunks
0
4
12
4
0
1
0
1
Configuring SLS
BRI
DS1
trunks
trunks
0
0
0
0
4
0
0
T1:23
E1:30
T1: 69 (FAS)
71 (NFAS)
E1: 90 (FAS)
92 (NFAS)