Configuring Standard Local Survivability (SLS)
2. Look for any of the following supported gateways in the Type field:
G250/G250-BRI/G250-DCP/G250-DS1
G350
3. Once you know the media gateway of interest, match the gateway model with the analog
station ports:
4. At the SAT, type display port port-number, where port-number is the analog
station port on the gateway, and press Enter.
The system displays the extension number assigned to the port.
5. Once you know the extension, type display station extension and press Enter to
display the Station form for this extension.
6. Gather the necessary information from
Table 12: Analog station form data to assemble for SLS
*
Page
Field Name
1
Extension
1
Port
1
Type
1
Survivable COR
1
Survivable Trunk Dest
2
Switchhook Flash
1
Name
* Page numbers might vary for your system.
128 Administration for the Avaya G250 and Avaya G350 Media Gateways
Gateway
Media module
model
(if applicable)
G250-Analog
G350
MM711
MM714
MM716
Slot V7
(ana-imm1t2l)
Notes
The port address correlates the analog stations that belong
to a particular media gateway. If the port ID includes the
media gateway number, then it is accepted. A new station
slot/port entry must include the "V", as in "V305".
Only 2500 is the accepted type.
Class of Restriction while in SLS mode
Trunk destination while in SLS mode
This field appears when Type is 2500.
This is the user's name
Slot
configuration
V3
Table
12.