Prerequisites
Avaya Communication Manager 2.2 or higher
●
FIPS-ready gateway
●
- Check the Material Code in
rear panel of the gateway.
- Use the show system command and verify that "FIPS ready" is displayed.
G350-N(super)# show system
HW Ready for FIPS: yes
Administration Procedures
Administration procedures consist of entering FIPS mode and the limitations and prerequisites
of doing so. It also includes failure scenarios and repair actions.
Limitations
The following rules and restrictions apply in FIPS-approved mode:
SSHv2 service must be shut down
●
Media encryption must be shut down
●
H.248 signalling must be shut down
●
The Announcement FTP server shall not be used for upload/download G350 executable
●
files or for file transfer of security-related data
ASG services logon must be shut down
●
ASG BP login must be shut down
●
Modem connections to the Console and USB ports must be shut down
●
Table
90. The material code is on the product label on the
Table 90: Material codes of FIPS-compliant media gateways
Media Gateway
G250
G250-BRI
G350
Administration Procedures
Material Code
700356231
700356223
700356249
Issue 3 February 2007
605