117

AN-1006

Recommended
No action is required.
Action
Severity
INFO
AN-1006
Message
<Sequence Number> AUDIT, <timestamp>, [AN-1006], INFO, FABRIC,
<event-initiator-details>, <event-location>, , Bottleneck detection configuration
is successfully changed.
Probable Cause
Indicates that the bottleneck detection configuration was changed by a user.
Recommended
No action is required.
Action
Severity
INFO

AN-1010

Message
<Sequence Number> AUDIT, <timestamp>, [AN-1010], WARNING, FABRIC,
<event-initiator-details>, <event-location>, , Severe latency bottleneck detected
at Slot <slot number> port <port number within slot number>.
Probable Cause
Indicates credit loss at the specified port, a downstream port, or a very high latency device at the
edge of the fabric.
Recommended
Contact your vendor's customer support for assistance.
Action
Severity
WARNING

AN-1011

Message
<Sequence Number> AUDIT, <timestamp>, [AN-1011], WARNING, FABRIC,
<event-initiator-details>, <event-location>, , Could not distinguish between
primary and dependent severe latency bottleneck on slot <slot number> port <port
number within slot number> because port mirroring is enabled on this port.
Probable Cause
Indicates that resources needed to determine whether there is complete credit loss on a VC at this
port are in use by port mirroring.
Recommended
Contact your vendor's customer support for assistance.
Action
Severity
WARNING
774