Recommended
Restart the switch. If the message persists, replace the switch.
Action
Severity
CRITICAL
BL-1039
Message
<timestamp>, [BL-1039], <sequence-number>,, CRITICAL, <system-name>, Inconsistent
FPGA image version detected, faulting the blade in slot <slot number>.
Probable Cause
Indicates that the FPGA image version is incompatible with the software version.
Recommended
Power cycle the blade. If the message persists, replace the blade.
Action
Severity
CRITICAL
BL-1041
Message
<timestamp>, [BL-1041], <sequence-number>,, CRITICAL, <system-name>, Dynamic area
mode is enabled on default switch, Faulting the blade w/ ID <Blade ID of blade
that has the mini SFP+ that does not support it> in slot <slot number> as it does
not support this mode.
Probable Cause
Indicates that the blade does not support dynamic area mode on default switch.
Recommended
Turn off the dynamic area mode through Configure CLI.
Action
Severity
CRITICAL
BL-1045
Message
<timestamp>, [BL-1045], <sequence-number>,, ERROR, <system-name>, mini SFP+ (SN:
<mini SFP+ serial number>) is only supported in certain high port count blades,
not blade in slot <slot number of blade that has the mini SFP+> w/ ID <Blade ID of
blade that has the mini SFP+ that does not support it>.
Probable Cause
Indicates that the mini (form factor) SFP+ is supported only by a certain type of blade (FC8-64),
but it can be inserted in other blades.
Recommended
Replace the mini SFP+ with an SFP or SFP+.
Action
Severity
ERROR
Fabric OS Message Reference
53-1002448-01
7
BL-1039