NS-1011

NS-1011
Message
<timestamp>, [NS-1011], <sequence-number>,, WARNING, <system-name>, NS has
detected a failover flag disabled TI zone in a base switch <domain id> in fabric
id <fabric id>.
Probable Cause
Indicates that a failover flag has disabled TI zone in a base switch fabric.
Recommended
Modify failover flag to enable or remove TI zone with failover flag disabled since the routing may not
Action
be setup correctly.
Severity
WARNING

NS-1012

Message
<timestamp>, [NS-1012], <sequence-number>,, WARNING, <system-name>, Detected
duplicate WWPN [<WWPN>] - devices removed with PID 0x<existing device PID> and
0x<new device PID>.
Probable Cause
Indicates that the devices with the same World Wide Port Name (WWPN) have been removed from
the Name Server database.
Recommended
Administrators should verify the reported devices with a duplicated WWPN.
Action
Severity
WARNING