Pdm-1004; Pdm-1005; Pdm-1006; Pdm-1007 - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

79

PDM-1004

PDM-1004
Message
<timestamp>, [PDM-1004], <sequence-number>,, WARNING, <system-name>, PDM memory
shortage.
Probable Cause
Indicates the parity data manager (PDM) process ran out of memory.
Recommended
Reboot or power cycle the switch.
Action
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
WARNING

PDM-1005

Message
<timestamp>, [PDM-1005], <sequence-number>,, WARNING, <system-name>, FSS register
failed.
Probable Cause
Indicates the parity data manager (PDM) failed to register with the Fabos Synchronization Service
(FSS).
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
WARNING

PDM-1006

Message
<timestamp>, [PDM-1006], <sequence-number>,, WARNING, <system-name>, Too many
files in sync.conf.
Probable Cause
Indicates the configuration file sync.conf contains too many entries.
Recommended
Run the firmwareDownload command to reinstall the firmware.
Action
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity
WARNING

PDM-1007

Message
<timestamp>, [PDM-1007], <sequence-number>,, WARNING, <system-name>, File not
created: <file name> errno= <errno>.
Probable Cause
Indicates the parity data manager (PDM) process failed to create the specified file.
534
Fabric OS Message Reference
53-1002448-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade 8/12cBrocade 8/24cFabric os v7.0.1

Table of Contents