FW-1432
Message
<timestamp>, [FW-1432], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor WWN: <Number Bad> bad.
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty World Wide Name (WWN) cards is greater than or equal to the policy set by the
switchStatusPolicySet command.
Recommended
Replace the faulty WWN card.
Action
Severity
WARNING
FW-1433
Message
<timestamp>, [FW-1433], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor CP: CP non-redundant.
Probable Cause
Indicates that the switch status is not in a healthy state. This occurred because the number of
faulty CPs is greater than or equal to the policy set by the switchStatusPolicySet command. The CPs
are non-redundant.
If you power cycle a Brocade 24000 chassis in dual-domain configuration, and then reset the
micro-switch of the active CP before the heartbeat is up, this will cause both CPs to come up in a
non-redundant state.
Recommended
Execute the firmwareShow command to verify that both CPs have compatible firmware levels.
Action
Execute the firmwareDownload command to install the same level of firmware to both CPs. Replace
any faulty CPs.
If you reset the micro-switch (the latch on the CP blade) on the active CP before the heartbeat was
up on a power cycle, and the CPs came up non-redundant, then you should reboot the CPs again to
clear the problem.
Severity
WARNING
FW-1434
Message
<timestamp>, [FW-1434], <sequence-number>,, WARNING, <system-name>, Switch status
change contributing factor Blade:
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the number of blade
failures is greater than or equal to the policy set by the switchStatusPolicySet command.
Recommended
Replace the faulty blade.
Action
Severity
WARNING
Fabric OS Message Reference
53-1002448-01
<Number Bad>
blade failures.
45
FW-1432
401