ZONE-1022

ZONE-1022
Message
<timestamp>, [ZONE-1022], <sequence-number>,, INFO, <system-name>, The effective
configuration has changed to <Effective configuration name>. <AD Id>
Probable Cause
Indicates that the effective zone configuration has changed to the specified zone name.
Recommended
Verify that the event was planned. If the event was planned, no action is required. If the event was
Action
not planned, take appropriate action as defined by your enterprise security policy.
Severity
INFO

ZONE-1023

Message
<timestamp>, [ZONE-1023], <sequence-number>,, INFO, <system-name>, Switch
connected to port (<port number>) is busy. Retrying zone merge.
Probable Cause
Indicates that the switch is retrying the merge operation. This usually occurs if the switch on the
other side of the port is busy.
Recommended
If the problem persists, execute supportFtp (as needed) to set up automatic FTP transfers; then
Action
execute the supportSave command and contact your switch service provider.
Severity
INFO

ZONE-1024

Message
<timestamp>, [ZONE-1024], <sequence-number>,, INFO, <system-name>, <Information
message>.
Probable Cause
Indicates that the cfgSave command has completed successfully.
Recommended
No action is required.
Action
Severity
INFO

ZONE-1026

Message
<timestamp>, [ZONE-1026], <sequence-number>,, INFO, <system-name>, port <port
number> Out of CAM entries.
Probable Cause
Indicates that the total number of S_ID entries for creating or adding a zone group exceeds the
limit.
Recommended
If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that
Action
port.
Severity
INFO