FICN-1040
Message
<timestamp>, [FICN-1040], <sequence-number>,, ERROR, <system-name>,
HostTapeEgr:Tape:CmdReject Sense Data Rcvd:Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr>LastCmds=0x<Last 4 commands
received from the channel for this device> SenseData:Bytes0-0xB=0x<Bytes 0-3 of
sense data from the device> <Bytes 4-7 of sense data from the device> <Bytes
8-0x0b of sense data from the device>.
Probable Cause
Indicates an active disk emulation device received a FICON Purge Path from the channel.
Recommended
If there was an unexpected job failure or IO Error associated with this event, contact your switch
Action
service provider.
Severity
ERROR
FICN-1041
Message
<timestamp>, [FICN-1041], <sequence-number>,, ERROR, <system-name>,
HostTapeEgr:AS Link Level Reject (LRJ) from CU Rx Path=<VEPortNumber HostDomain
HostPort DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr>LastCmd=0x<Last 4
commands issued to this device from the channel> LastStatus=0x<Last 4 status
values sent to the channel from this device>.
Probable Cause
Indicates an LRJ received from a device indicates that the CU has lost the logical path to the LPAR.
Recommended
If this was an unexpected event, contact your vendor's customer support for assistance.
Action
Severity
ERROR
FICN-1042
Message
<timestamp>, [FICN-1042], <sequence-number>,, WARNING, <system-name>,
HostTapeIng:FICON Cancel received Path=<VEPortNumber HostDomain HostPort
DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr> state=0x<the current emulation
state for this device>.
Probable Cause
Indicates a job was cancelled during a write pipelining.
Recommended
If this was an unexpected event (cancel is normally an operator event), contact your vendor's
Action
customer support for assistance.
Severity
WARNING