UPTH System Messages

UPTH-1001

Message
<timestamp>, [UPTH-1001], <sequence-number>,, WARNING, <system-name>, No minimum
cost path in candidate list.
Probable Cause
Indicates the specified switch is unreachable because no minimum cost path (FSPF UPATH) exists
in the candidate list (domain ID list).
Recommended
No action is required. This will end the current SPF computation.
Action
Severity
WARNING

UPTH-1002

Message
<timestamp>, [UPTH-1002], <sequence-number>,, WARNING, <system-name>, Domain
<domain ID> is unreachable because the enabled TI zone is not compatible with the
fabric configuration.
Probable Cause
Indicates the specified switch is unreachable because of the TI zone and the fabric configuration
incompatibility.
Recommended
Clear all TI zones and refer to the TI zone user manual for instructions on how to create a valid TI
Action
zone for your fabric configuration.
Severity
WARNING
Fabric OS Message Reference
53-1002448-01
Chapter
110