HIL System Messages

HIL-1101

Message
<timestamp>, [HIL-1101], <sequence-number>,, ERROR, <system-name>, Slot <slot
number> faulted, <nominal voltage> (<measured voltage>) is above threshold.
Probable Cause
Indicates that the blade voltage is above threshold.
Recommended
Replace the faulty blade or switch (for nonbladed switches).
Action
Severity
ERROR

HIL-1102

Message
<timestamp>, [HIL-1102], <sequence-number>,, ERROR, <system-name>, Slot <slot
number> faulted, <nominal voltage> (<measured voltage>) is below threshold.
Probable Cause
Indicates that the blade voltage is below threshold.
Recommended
Replace the faulty blade or switch (for nonbladed switches).
Action
Severity
ERROR

HIL-1103

Message
<timestamp>, [HIL-1103], <sequence-number>,, ERROR, <system-name>, Blower <blower
number> faulted, <nominal voltage> (<measured voltage>) is above threshold.
Probable Cause
Indicates that the fan voltage is above threshold.
Recommended
Run the psShow command to verify the power supply status.
Action
Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they
are seated properly.
If the problem persists, replace the fan FRU or the power supply FRU as necessary.