45
FW-1047
FW-1047
Message
<timestamp>, [FW-1047], <sequence-number>,, WARNING, <system-name>, <Label>, is
above high boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has risen above the high
boundary.
Recommended
The supplied current of the SFP transceiver is outside of the normal range, indicating possible
Action
hardware failure. If the current rises above the high boundary, you must replace the SFP.
Severity
WARNING
FW-1048
Message
<timestamp>, [FW-1048], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed from a value
outside of the acceptable range to a value within the acceptable range.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation.
Severity
INFO
FW-1049
Message
<timestamp>, [FW-1049], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has changed.
Recommended
Frequent voltage fluctuations indicate that the SFP is deteriorating. Replace the SFP.
Action
Severity
INFO
FW-1050
Message
<timestamp>, [FW-1050], <sequence-number>,, WARNING, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the value of the small form-factor pluggable (SFP) voltage has fallen below the low
boundary.
348
Fabric OS Message Reference
53-1002448-01