BL-1031
Message
<timestamp>, [BL-1031], <sequence-number>,, CRITICAL, <system-name>, Link timeout
in internal port (slot <Slot number>, port <Port number>) resulted in blade fault.
Use slotpoweroff/slotpoweron to recover the blade.
Probable Cause
Indicates that link timeout occurred in one of the backend internal ports.
Recommended
Power cycle the blade or run the slotPowerOff and slotPowerOn commands.
Action
Severity
CRITICAL
BL-1032
Message
<timestamp>, [BL-1032], <sequence-number>,, CRITICAL, <system-name>, (slot <slot
number>,bitmap 0x<object control flags(bitmap)>) ports never came up ONLINE
(reason <reason for port disable>, state <status of the blade>). Disabling slot.
Probable Cause
Indicates that back-end (non-user) ports have not come ONLINE within time limit.
Recommended
Restart or power cycle the blade. Run the diagPost command to ensure that Power-On Self-Test
Action
(POST) is enabled. If the message persists, replace the blade.
Severity
CRITICAL
BL-1033
Message
<timestamp>, [BL-1033], <sequence-number>,, CRITICAL, <system-name>, (slot <slot
number>,bitmap 0x<object control flags(bitmap)>) No disable acknowledgment from
ports (state <status of the blade>). Disabling slot.
Probable Cause
Indicates that the system has timed out while waiting for disable messages from the user ports
after disabling the ports.
Recommended
Restart or power cycle the blade. Run the diagPost command to ensure that Power-On Self-Test
Action
(POST) is enabled. If the message persists, replace the blade.
Severity
CRITICAL
BL-1034
Message
<timestamp>, [BL-1034], <sequence-number>,, INFO, <system-name>, Slot
number>
Probable Cause
Indicates that the slot has completed initializing Fibre Channel (FC) ports.
Fabric OS Message Reference
53-1002448-01
FC Initialization completed.
7
BL-1031
<slot
81