Recommended
Whenever this error is observed persistently, power cycle the specified blade. If the problem
Action
persists, replace the blade.
Severity
WARNING
CDR-1016
Message
<timestamp>, [CDR-1016], <sequence-number>,, ERROR, <system-name>, Port is
faulted due to port re-initialization failure on internal Port S<slot
number>,P<port number>(<blade port number>) with reason <port fault reason>.
Probable Cause
Indicates that port is faulted due to port re-initialization failure.
Recommended
Whenever this error is observed persistently, power cycle the specified blade. If the problem
Action
persists, replace the blade.
Severity
ERROR
CDR-1017
Message
<timestamp>, [CDR-1017], <sequence-number>,, ERROR, <system-name>, Blade in Slot
<slot number> faulted due to unavailable ports in internal Trunk.
Probable Cause
Indicates that blade is faulted due to unavailable ports in internal trunk.
Recommended
Whenever this error is observed persistently, power cycle the specified blade. If the problem
Action
persists, replace the blade.
Severity
ERROR
CDR-1018
Message
<timestamp>, [CDR-1018], <sequence-number>,, ERROR, <system-name>, Blade in Slot
<slot number> faulted due to Link reset threshold value exceeded.
Probable Cause
Indicates that blade is faulted due to Link reset threshold exceeded.
Recommended
Whenever this error is observed persistently, power cycle the specified blade. If the problem
Action
persists, replace the blade.
Severity
ERROR
CDR-1019
Message
<timestamp>, [CDR-1019], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached type =
0x<chip error type>.
Probable Cause
Indicates an internal error in the ASIC hardware that may degrade data traffic.
Fabric OS Message Reference
53-1002448-01
15
CDR-1016
119