BM-1007
Message
<timestamp>, [BM-1007], <sequence-number>,, INFO, <system-name>, If set, clear
EX/VEX/FC Fastwrite configuration for all ports for blade in slot <Slot number>
Probable Cause
Indicates the specified blade was detected for the first time after an FR4-18i was previously
configured in the same slot. The new blade requires the specified port configurations to be cleared.
Recommended
No action is required. The blade ports are cleared automatically.
Action
Severity
INFO
BM-1008
Message
<timestamp>, [BM-1008], <sequence-number>,, WARNING, <system-name>, Download of
blade firmware failed for blade in slot <slot>
recover.
Probable Cause
Indicates the automatic firmware upgrade on the blade has failed, because the blade firmware
version was detected to be different from the control processor (CP) firmware version due to a
firmware upgrade.
Recommended
Issue the firmwareDownload command to recover the blade.
Action
Severity
WARNING
BM-1009
Message
<timestamp>, [BM-1009], <sequence-number>,, WARNING, <system-name>,
Firmwaredownload timed-out for application processor. Faulting switch.
Probable Cause
Indicates the firmwareDownload on the application processor (AP) blade failed.
Recommended
Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade
Action
7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit.
Severity
WARNING
BM-1010
Message
<timestamp>, [BM-1010], <sequence-number>,, INFO, <system-name>, Resetting port
configuration and linkcost for all ports for blade in slot <Slot number>.
Probable Cause
Indicates the specified blade was detected for the first time after an FC10-6 was previously
configured in the same slot. The new blade requires resetting the port configuration and linkcost.
Fabric OS Message Reference
53-1002448-01
BM-1007
.
Reissue firmwaredownload to
10
.