Fw-1004; Fw-1009; Fw-1010 - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

45

FW-1004

Recommended
This message generally appears when a fan fails. If so, a fan failure message accompanies this
Action
message. Replace the fan field-replaceable unit (FRU).
Severity
WARNING
FW-1004
Message
<timestamp>, [FW-1004], <sequence-number>,, INFO, <system-name>, <Label>, is
between high and low boundaries(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.
Probable Cause
Indicates that the internal temperature of the switch has changed from a value outside of the
acceptable range to a value within the acceptable range.
Recommended
No action is required. Respond to this message as is appropriate to the particular policy of the
Action
end-user installation. If you receive a temperature-related message, check for an accompanying
fan-related message and check fan performance. If all fans are functioning normally, check the
climate control in your lab.
Severity
INFO

FW-1009

Message
<timestamp>, [FW-1009], <sequence-number>,, INFO, <system-name>, <Label>, value
has changed(High=<High value>, Low=<Low value>). Current value is <Value> <Unit>.
Probable Cause
Indicates that the state of the power supply has changed from faulty to functional, or from
functional to faulty.
Recommended
If the power supply is functioning correctly, no action is required.
Action
If the power supply is functioning below the acceptable boundary, verify that it is seated correctly in
the chassis. Run the psShow command to view the status of the power supply. If the power supply
continues to be a problem, replace the faulty power supply.
Severity
INFO

FW-1010

Message
<timestamp>, [FW-1010], <sequence-number>,, WARNING, <system-name>, <Label>, is
below low boundary(High=<High value>, Low=<Low value>). Current value is <Value>
<Unit>.
Probable Cause
Indicates that the power supply is faulty. The power supply is not producing enough power.
Recommended
Verify that you have installed the power supply correctly and that it is correctly seated in the
Action
chassis. If the problem persists, replace the faulty power supply.
Severity
WARNING
342
Fabric OS Message Reference
53-1002448-01