3
AN-1004
AN-1004
Message
<timestamp>, [AN-1004], <sequence-number>,, WARNING, <system-name>, Congestion
bottleneck on port <slot number>/<port number within slot number>. <percentage of
seconds affected by congestion bottlenecking> pct. of <observation period over
which the percentage of affected seconds is reported> secs. affected.
Probable Cause
Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.
Recommended
Add more capacity on the path, using trunk links if possible.
Action
Severity
WARNING
AN-1005
Message
<timestamp>, [AN-1005], <sequence-number>,, INFO, <system-name>, Slot <slot
number>, port <port number within slot number> has <bottleneck type> bottleneck
cleared.
Probable Cause
Indicates that the bottleneck was cleared on the port.
Recommended
No action is required.
Action
Severity
INFO
AN-1010
Message
<timestamp>, [AN-1010], <sequence-number>,, WARNING, <system-name>, Severe
latency bottleneck detected at Slot <slot number> port <port number within slot
number>.
Probable Cause
Indicates credit loss at the specified port, a downstream port, or a very high latency device at the
edge of the fabric.
Recommended
Contact your vendor's customer support for assistance.
Action
Severity
WARNING
AN-1011
Message
<timestamp>, [AN-1011], <sequence-number>,, WARNING, <system-name>, Could not
distinguish between primary and dependent severe latency bottleneck on slot <slot
number> port <port number within slot number> because port mirroring is enabled on
this port.
Probable Cause
Indicates that resources needed to determine whether there is complete credit loss on a VC at this
port are in use by port mirroring.
48
Fabric OS Message Reference
53-1002448-01