Anv-1008; Anv-1015; Anv-1016 - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

ANV-1008

Message
<timestamp>, [ANV-1008], <sequence-number>,, ERROR, <switch-name>, S<slot
number>, C<chip index>: MAC-VID classifier table is full. No space for new entry.
Probable Cause
Indicates that the Media Access Control (MAC) VLAN ID (VID) classifier table is full and no more
entries can be added.
Recommended
Delete some of the existing unused rules using the portcfg arp command and then add new
Action
entries.
Severity
ERROR

ANV-1015

Message
<timestamp>, [ANV-1015], <sequence-number>,, WARNING, <switch-name>, Port
reinitialized due to Link Reset failure on internal port S<slot number>, P<port
number>(<blade port number>).
Probable Cause
Indicates that the specified port was reinitialized due to link reset failure.
Recommended
Power cycle the faulted blade. If the problem persists, replace the faulted blade.
Action
Severity
WARNING

ANV-1016

Message
<timestamp>, [ANV-1016], <sequence-number>,, WARNING, <switch-name>, Port is
faulted due to port reinitialization failure on internal port S<slot number>,
P<port number>(<blade port number>) with reason <port fault reason>.
Probable Cause
Indicates that the specified port is faulted due to port reinitialization failure.
Recommended
Power cycle the faulted blade. If the problem persists, replace the faulted blade.
Action
Severity
WARNING
Fabric OS Message Reference