AUDIT AN System Messages

AN-1003

Message
<Sequence Number> AUDIT, <timestamp>, [AN-1003], WARNING, FABRIC,
<event-initiator-details>, <event-location>, , Latency bottleneck on port <slot
number>/<port number within slot number>. <percentage of seconds affected by
latency bottlenecking> pct. of <observation period over which the percentage of
affected seconds is reported> secs. affected. Avg. time b/w transmits <observed
average time between frames during affected seconds> us. Avg. slowdown <observed
throughput drop factor during affected seconds>.
Probable Cause
For an F_Port, it indicates that the attached device is slow in responding to frames going out of this
port. This latency may be inherent in the device or due to heavy workload on the device. For an
E_Port, it indicates a downstream primary bottleneck.
Recommended
If the port is an F_Port, examine the connected device for the source of the latency. If the port is a
Action
long-distance E_Port, ensure that there are enough buffer credits to service the link distance.
Severity
WARNING

AN-1004

Message
<Sequence Number> AUDIT, <timestamp>, [AN-1004], WARNING, FABRIC,
<event-initiator-details>, <event-location>, , Slot <slot number>, port <port
number within slot number> is a congestion bottleneck. <percentage of seconds
affected by congestion bottlenecking> percent of last <observation period over
which the percentage of affected seconds is reported> seconds were affected by
this condition.
Probable Cause
Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.
Recommended
Add more capacity on the path, using trunk links if possible.
Action
Severity
WARNING

AN-1005

Message
<Sequence Number> AUDIT, <timestamp>, [AN-1005], INFO, FABRIC,
<event-initiator-details>, <event-location>, , Slot <slot number>, port <port
number within slot number> has <bottleneck type> bottleneck cleared.
Probable Cause
Indicates that the bottleneck was cleared on the port.