39

FICU-1004

FICU-1004
Message
<timestamp>, [FICU-1004], <sequence-number>,, WARNING, <system-name>, <function
name>: Failed to set fabric manager server (FMS) mode: conflicting PID
Format:<pid_format>, FMS Mode:<mode>.
Probable Cause
Indicates that a process ID (PID) format conflict was encountered. The core PID format is required
for FICON-CUP.
The pid_format variable displays the PID format currently running on the fabric, and is one of the
following:
The mode variable displays whether FICON Management Server (FMS) mode is enabled, and is one
of the following:
Recommended
To enable FMS mode, the core PID format must be used in the fabric. Change the PID format to
Action
core PID using the configure command and then re-enable FMS mode using the ficonCupSet
command.
Severity
WARNING

FICU-1005

Message
<timestamp>, [FICU-1005], <sequence-number>,, ERROR, <system-name>, Failed to
initialize <module>, rc = <error>.
Probable Cause
Indicates that the initialization of the specified module within the FICON-CUP daemon failed.
Recommended
Download a new firmware using the firmwareDownload command.
Action
Severity
ERROR

FICU-1006

Message
<timestamp>, [FICU-1006], <sequence-number>,, WARNING, <system-name>, Control
Device Allegiance Reset: (Logical Path: 0x<PID>:0x<channel image ID>).
Probable Cause
Indicates that the logical path with the specified PID and channel image ID lost allegiance to a
FICON-CUP device.
Recommended
Check if the FICON channel corresponding to the PID in the message is functioning properly.
Action
Severity
WARNING
322
0 – VC-encoded PID format
1 – core PID format
2 – extended-edge PID format
0 – FMS is enabled
1 – FMS is disabled
Fabric OS Message Reference