Em-1059; Em-1060; Em-1061 - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

25

EM-1059

EM-1059
Message
<timestamp>, [EM-1059], <sequence-number>, FFDC, ERROR, <system-name>, <Slot
number or Switch> with ID <Blade Id> may not be supported on this platform, check
FOS firmware version as a possible cause.
Probable Cause
Indicates that a blade inserted in the specified slot or the switch (for nonbladed switches) is
incompatible with the switch configuration software. The system may not be usable. The blade may
only be supported by a later (or earlier) version of the firmware.
Recommended
Change the control processor (CP) firmware or replace the blade. Make sure the replacement is
Action
compatible with your switch type and firmware.
Severity
ERROR

EM-1060

Message
<timestamp>, [EM-1060], <sequence-number>,, WARNING, <system-name>, Stopping
synchronization of the system due to blade incompatibility with software version
on standby CP.
Probable Cause
Indicates that a blade in the system is not supported by the release on the standby control
processor (CP).
Recommended
Remove all blades of this type or upgrade your standby CP. After an appropriate action is taken,
Action
restart the standby CP or execute the haSyncStart command to enable the High Availability (HA)
state synchronization. Until this is done, the system will remain out of synchronization.
Severity
WARNING

EM-1061

Message
<timestamp>, [EM-1061], <sequence-number>,, WARNING, <system-name>,
Synchronization halted. Remove all blades of type <Blade Type Id> or upgrade your
standby CP, then reboot or run haSyncStart.
Probable Cause
Indicates a blade in the system is not supported by the firmware on the standby control processor
(CP).
Recommended
Remove all blades of the specified type or upgrade the standby CP. After an appropriate action is
Action
taken, restart the standby CP or execute the haSyncStart command to enable the High Availability
(HA) state synchronization. Until this is done, the system will remain out of synchronization.
Severity
WARNING
194
Fabric OS Message Reference
53-1002448-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade 8/12cBrocade 8/24cFabric os v7.0.1

Table of Contents