Recommended
Restart or power cycle the switch.
Action
If the problem persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.
Severity
ERROR
EM-1069
Message
<timestamp>, [EM-1069], <sequence-number>,, INFO, <system-name>, Slot <FRU slot
number> is being powered off.
Probable Cause
Indicates that the blade in the specified slot is being intentionally powered off.
Recommended
No action is required.
Action
Severity
INFO
EM-1070
Message
<timestamp>, [EM-1070], <sequence-number>,, INFO, <system-name>, Slot <FRU slot
number> is being powered on.
Probable Cause
Indicates that the blade in the specified slot is being intentionally powered on.
Recommended
No action is required.
Action
Severity
INFO
EM-1071
Message
<timestamp>, [EM-1071], <sequence-number>, FFDC, CRITICAL, <system-name>, Unit in
<Slot number> with ID <FRU Id> is faulted, it is incompatible with the following
blade id(s): <blade incompatibility list>.
Probable Cause
Indicates that a blade inserted in the specified slot is incompatible with another blade in the
system.
Recommended
Determine which blade is essential to your configuration and remove blades that are incompatible
Action
to it.
Severity
CRITICAL
Fabric OS Message Reference
53-1002448-01
25
EM-1069
197