17

CHS-1005

CHS-1005
Message
<timestamp>, [CHS-1005], <sequence-number>,, ERROR, <system-name>, Diag attach
failed during recovery, disabling slot = <slot number>.
Probable Cause
Indicates that the Diag blade attach has failed during failover or recovery.
Recommended
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
Action
command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900,
5000, 7500, or AP7600 switch, reboot or power cycle the switch.
Severity
ERROR