Swch-1008; Swch-1009; Swch-1010 - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

Recommended
Based on the disable reason displayed, proper corrective action may to be required to restore the
Action
port.
If the disable reason is due to insufficient frame buffers, reduce the distance or speed settings for
the port to reduce the buffer requirement of the link. Alternatively, one or more ports in the port
group must be disabled to make more buffers available for the link.
Refer to the Fabric OS Administrator's Guide for more information about buffers.
Severity
WARNING

SWCH-1008

Message
<timestamp>, [SWCH-1008], <sequence-number>,, WARNING, <system-name>, <area
string> are port swapped on ports that do not support port swap. Slot <slot
number> will be faulted.
Probable Cause
Indicates the blade is enabled with the port configuration that does not support port swap.
Recommended
Replace the blade with ports that support port swap. Then swap the ports back to the ports default
Action
area.
Refer to the Fabric OS Administrator's Guide for more information on port swapping.
Severity
WARNING

SWCH-1009

Message
<timestamp>, [SWCH-1009], <sequence-number>,, WARNING, <system-name>, Shared area
having Trunk Area (TA) enabled on slot <slot number>. Shared areas that have TA
enabled will be persistenly disabled.
Probable Cause
Indicates the blade is enabled with a port configuration that had Trunk Area previously enabled on
a shared area port.
Recommended
You must disable Trunk Area on ports that had Trunk Area enabled previously.
Action
Refer to the Fabric OS Administrator's Guide for more information.
Severity
WARNING

SWCH-1010

Message
<timestamp>, [SWCH-1010], <sequence-number>,, WARNING, <system-name>, Trunk Area
(TA) enabled on slot <slot number> with switch not in PID format 1. TA enabled
ports will be persistently disabled.
Probable Cause
Indicates the blade is enabled with the port configuration that had Trunk Area enabled previously.
Recommended
You must disable Trunk Area on ports that had Trunk Area enabled previously.
Action
Fabric OS Message Reference
53-1002448-01
102
SWCH-1008
709