Cvlm-1001; Cvlm-1002; Cvlm-1003; Cvlm System Messages - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

CVLM System Messages

CVLM-1001

Message
<timestamp>, [CVLM-1001], <sequence-number>,, ERROR, <system-name>, Failed to
allocate memory: (<function name>).
Probable Cause
Indicates that the specified function has failed to allocate memory.
Recommended
Check the memory usage on the switch using the memShow command. Restart or power cycle the
Action
switch.
Severity
ERROR

CVLM-1002

Message
<timestamp>, [CVLM-1002], <sequence-number>,, ERROR, <system-name>, Failed to
initialize <module> rc = <error>.
Probable Cause
Indicates that an initialization of a module within the CVLMD has failed.
Recommended
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Action
Command Reference Manual for more information on this command.
Severity
ERROR

CVLM-1003

Message
<timestamp>, [CVLM-1003], <sequence-number>,, INFO, <system-name>, Crypto device
configuration has been committed by switch (<Switch WWN>).
Probable Cause
Indicates that the switch has committed a crypto device configuration.
Recommended
No action is required.
Action
Severity
INFO
Fabric OS Message Reference