102

SWCH-1018

Recommended
This is a LOOP device and peristent PID is set on it. This is not a supported configuration. Remove
Action
the WWN-PID binding and re-enable the port and then run the wwnaddress
command.
Severity
INFO
SWCH-1018
Message
<timestamp>, [SWCH-1018], <sequence-number>,, INFO, <system-name>, Device <wwn
name of device> flogis to port <port number>, Static persistent PID set, Requested
area <area> user bound to another port. Reject FLOGI.
Probable Cause
Indicates WWN-PID and PortAddress binding collision.
Recommended
The Peristent PID is set on device and requested area cannot be assigned as its user is bound to a
Action
different port. Remove the WWN-PID binding or remove portAddress binding and re-enable the port
and then run the wwnaddress
Severity
INFO

SWCH-1019

Message
<timestamp>, [SWCH-1019], <sequence-number>,, INFO, <system-name>, Device <wwn
name of device> tries to flogi, reject FLOGI as persistent PID is set on device
and port <port number> has user area <area> bound to it.
Probable Cause
Indicates a WWN-PID and PortAddress binding collision.
Recommended
The Peristent PID is set on the device and requested area cannot be assigned because its user is
Action
bound to a different port. Remove the WWN-PID binding or remove portAddress binding and
re-enable the port and then run the wwnaddress
command.
Severity
INFO

SWCH-1020

Message
<timestamp>, [SWCH-1020], <sequence-number>,, WARNING, <system-name>, HA state
out of sync: Standby CP (ver = <standby SWC version>) does not support QOS links
to AG (Active CP version = <active SWC version>).
Probable Cause
Indicates the standby control processor (CP) does not support links to AG running QOS.
Recommended
Load a firmware version on the standby CP that supports QOS links to AG, using the
Action
firmwareDownload command.
Severity
WARNING
712
unbind wwn or portaddress
--
unbind wwn or portaddress
--
unbind wwn
--
unbind slot/port command.
--
unbind slot/port
--
Fabric OS Message Reference