Recommended
Whenever this error is observed persistently, power cycle the specified blade. If the problem
Action
persists, replace the blade.
Severity
ERROR
C2-1017
Message
Message <timestamp>, [C2-1017], <sequence-number>,, ERROR, <system-name>, Blade
in Slot <slot number> failed due to unavailability of ports in the internal trunk.
Probable Cause
Indicates that the blade failed due to unavailability of the ports in the internal trunk.
Recommended
Whenever this error is observed persistently, power cycle the specified blade. If the problem
Action
persists, replace the blade.
Severity
ERROR
C2-1018
Message
Message <timestamp>, [C2-1018], <sequence-number>,, ERROR, <system-name>, Blade
in Slot <slot number> faulted due to Link reset threshold value exceeded.
Probable Cause
Indicates that blade is faulted due to Link reset threshold exceeded.
Recommended
Whenever this error is observed persistently, power cycle the specified blade. If the problem
Action
persists, replace the blade.
Severity
ERROR
C2-1019
Message
Message <timestamp>, [C2-1019], <sequence-number>,, WARNING, <system-name>,
S<slot number>,C<chip index>: HW ASIC Chip TXQ FID parity error threshold reached
type = 0x<chip error type>.
Probable Cause
Indicates that an internal error is observed in the ASIC hardware that may degrade the data traffic.
Recommended
Whenever this error occurs, restart the system at the next maintenance window.
Action
Severity
WARNING