Em-1033; Em-1034 - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

25

EM-1033

Recommended
Close the ejector switch (raise the slider in most blades, or completely screw in the upper
Action
thumbscrew for the FC4-48 port blade) if the field-replaceable unit (FRU) is intended for use. Refer
to the appropriate Hardware Refernce Manual for instructions on inserting the switch blades.
Severity
ERROR
EM-1033
Message
<timestamp>, [EM-1033], <sequence-number>,, ERROR, <system-name>, CP in <FRU Id>
set to faulty because CP ERROR asserted.
Probable Cause
Indicates that the standby control processor (CP) has been detected as faulty. The High Availability
(HA) feature will not be available. This message occurs every time the other CP reboots, even as
part of a clean warm failover. In most situations, this message is followed by the EM-1047
message, and no action is required for the CP; however, find the reason for failover.
Recommended
If the standby CP was restarted, wait for the error to clear (execute the slotShow command to
Action
determine if it has cleared). Watch for the EM-1047 message to verify that this error has cleared.
If the standby CP continues to be faulty or if it was not intentionally restarted, check the error logs
on the other CP (using the errDump command) to determine the cause of the error state.
Reseat the field-replaceable unit (FRU). If the problem persists, replace the FRU.
Severity
ERROR

EM-1034

Message
<timestamp>, [EM-1034], <sequence-number>,, ERROR, <system-name>, <FRU Id> set to
faulty, rc=<return code>.
Probable Cause
Indicates that the specified field-replaceable unit (FRU) has been marked as faulty for the specified
reason.
Recommended
Reseat the FRU.
Action
Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then
power cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's
ejector switch cycled to run POST and verify that the blade does not have any hardware problems.
If the problem persists, replace the FRU.
Severity
ERROR
188
Fabric OS Message Reference
53-1002448-01