19
CONF-1021
CONF-1021
Message
<timestamp>, [CONF-1021], <sequence-number>,, INFO, <system-name>, configUpload
not permitted <AD Number if AD is configured on the system>.
Probable Cause
Indicates a configUpload operation is not permitted. There are many possible causes.
Recommended
Execute the errShow command to view the error log. Correct the error and execute the
Action
configUpload command again.
Severity
INFO
CONF-1022
Message
<timestamp>, [CONF-1022], <sequence-number>,, WARNING, <system-name>, Downloading
configuration without disabling the switch was unsuccessful.
Probable Cause
Indicates an attempt to download the configuration without disabling the switch was unsuccessful
because there are one or more parameters that require the switch to be disabled.
Recommended
Disable the switch using the switchDisable command and download the configuration.
Action
Severity
WARNING
CONF-1023
Message
<timestamp>, [CONF-1023], <sequence-number>,, INFO, <system-name>, configDownload
failed <Message>.
Probable Cause
Indicates a configDownload operation has failed.
Recommended
Execute the errShow command to view the error log. Correct the error and execute the
Action
configDownload command again.
Severity
INFO
CONF-1024
Message
<timestamp>, [CONF-1024], <sequence-number>,, INFO, <system-name>, configUpload
failed <Message>.
Probable Cause
Indicates a configUpload operation has failed.
Recommended
Execute the errShow command to view the error log. Correct the error and execute the
Action
configUpload command again.
Severity
INFO
146
Fabric OS Message Reference
53-1002448-01