29
FABR-1047
FABR-1047
Message
<timestamp>, [FABR-1047], <sequence-number>, INFO, <system-name>, Area
unavailable to assign to the port. Persistently disabling port <Port that is being
disabled>.
Probable Cause
Indicates that there are no areas available to assign to the port during port creation.
Recommended
Move some ports out of the default switch to make areas available.
Action
Severity
INFO
FABR-1048
Message
<timestamp>, [FABR-1048], <sequence-number>,, ERROR, <system-name>, Detected
Fabric ID (FID <InheritedFID> inherited) conflict with switch <Switchname> (domain
<Domain ID>, FID <Fabric ID>).
Probable Cause
Indicates that a switch in the fabric has a Fabric ID conflict with the inherited FID of the local
switch.
Recommended
Make sure that all the switches in the fabric have same Fabric ID or upgrade the switch firmware to
Action
a VF-capable firmware.
Severity
ERROR
FABR-1049
Message
<timestamp>, [FABR-1049], <sequence-number>,, ERROR, <system-name>, Detected
Fabric ID (FID <InheritedFID> inherited) conflict with neighbor switch
<Switchname> (domain <Domain ID>, FID <Fabric ID>).
disabled>) connected to the switch are disabled.
Probable Cause
Indicates that the neighbor switch has Fabric ID conflict with the inherited FID of the local switch.
All E_ports directly connected to the conflicting switch are disabled.
Recommended
Make sure that all the switches in the fabric have same Fabric ID or upgrade the switch firmware to
Action
a VF-capable firmware.
Severity
ERROR
FABR-1050
Message
<timestamp>, [FABR-1050], <sequence-number>,, INFO, <system-name>, <License>
license not present. F-port trunking cannnot be enabled on port(<Port>).
Probable Cause
Indicates that the Trunking or SAO license is not installed.
222
E-ports (<Number of E-ports
Fabric OS Message Reference
53-1002448-01