Recommended
For status code 14, complete primary KEK generation; otherwise, contact your switch service
Action
provider.
Severity
ERROR
SPC-3007
Message
<timestamp>, [SPC-3007], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: DEK create error: <SP status code>,
info: <other info>.
Probable Cause
Indicates the cause depends on the SP status code:
•
•
•
•
•
•
Recommended
For status code 14, complete primary KEK generation; otherwise, contact your switch service
Action
provider.
Severity
ERROR
SPC-3008
Message
<timestamp>, [SPC-3008], <sequence-number>,, INFO, <system-name>, S<slot number
containing Encryption Engine>, <module name>: SP crypto got READY notification.
Probable Cause
Indicates the key application (KPD) within the Crypto Module of the EE has been started.
Recommended
No action is required.
Action
Severity
INFO
SPC-3009
Message
<timestamp>, [SPC-3009], <sequence-number>,, ERROR, <system-name>, S<slot number
containing Encryption Engine>, <module name>: FIPS certificate mismatch,
certificate: <FIPS certificate is CO-0 or User-1>.
Probable Cause
Indicates the FIPS certificate within the Crypto Module does not match that of the node.
Recommended
Zeroize the EE (after backing up any needed primary or secondary KEK), then execute the cryptocfg
Action
initEE and cryptocfg
--
Severity
ERROR
Fabric OS Message Reference
53-1002448-01
2 - Invalid input DEK specification
21 - No primary KEK exists with which to wrap the DEK
14 - Creation not allowed: primary KEK generation is in progress
31 - DEK could not be wrapped
73 - Invalid KEK format
other - Internal error
regEE commands.
--
97
SPC-3007
657