EM-1051

Message
<timestamp>, [EM-1051], <sequence-number>,, INFO, <system-name>, <FRU Id>:
Inconsistency detected, FRU reinitialized.
Probable Cause
Indicates that an inconsistent state was found in the field-replaceable unit (FRU). This occurs if the
state of the FRU was changing during a failover. The FRU is reinitialized and the traffic may have
been disrupted.
Recommended
No action is required.
Action
Severity
INFO

EM-1057

Message
<timestamp>, [EM-1057], <sequence-number>,, WARNING, <system-name>, Blade:<Slot
Id> is getting reset:<Fault reason>.
Probable Cause
Indicates the blade is being automatically reset because of known resetable transient errors such
as an application-specific integrated circuit (ASIC) parity error.
Recommended
No action is required if the switch does not reach the reset threshold for the switch or blade. If the
Action
reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be
replaced.
Severity
WARNING

EM-1058

Message
<timestamp>, [EM-1058], <sequence-number>,, WARNING, <system-name>, Switch gets
reset:<Fault reason>.
Probable Cause
Indicates that the switch is being automatically reset because of a known resetable transient
problem such as an application-specific integrated circuit (ASIC) parity error.
Recommended
No action is required if the switch does not reach the reset threshold for the switch or blade. If the
Action
reset threshold is reached on the switch or blade, the switch or blade will be faulted and should be
replaced.
Severity
WARNING
Fabric OS Message Reference