SYSC System Messages

SYSC-1001

Message
<timestamp>, [SYSC-1001], <sequence-number>, FFDC, CRITICAL, <system-name>,
Failed to run <Name of program that could not be run (string)>:<System internal
error message (string)>.
Probable Cause
Indicates that during the boot sequence, one of the programs does not run on the system.
Recommended
If the message is reported during a restart after new firmware has been loaded, try reloading the
Action
firmware using the firmwareDownload command.
If the message persists, there might be a conflict between the two versions of firmware or the
nonvolatile storage might be corrupted. Run supportFtp (as needed) to set up automatic FTP
transfers and run the supportSave command then contact your switch service provider.
Severity
CRITICAL

SYSC-1002

Message
<timestamp>, [SYSC-1002], <sequence-number>, FFDC, CRITICAL, <system-name>,
Switch bring-up timed out.
Probable Cause
Indicates the system has timed out during a restart or failover sequence, waiting for one or more
programs to register with system services or to fail over to active status.
Recommended
The switch is in an inconsistent state and can be corrected only by a restart or power cycle. Before
Action
restarting the chassis, record the firmware version on the switch or control processor (CP) and run
the haDump command. If this is a dual-CP switch, then gather the output from the CP in which this
log message appeared.
Severity
CRITICAL

SYSC-1003

Message
<timestamp>, [SYSC-1003], <sequence-number>, FFDC, CRITICAL, <system-name>,
Chassis config option <Option number read from the chassis option storage device>
is not supported by CP Blade with ID <Blade ID (platform) number from the Active
CP>. Change the chassis configuration <Steps to change chassis configuration>
Probable Cause
Indicates that on system startup, the option configuration file corresponding to the chassisConfig
option read could not be found. This indicates that option is not supported on this platform running
this version of the firmware.