Chs-1002; Chs-1003; Chs-1004; Chs System Messages - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

CHS System Messages

CHS-1002

Message
<timestamp>, [CHS-1002], <sequence-number>, FFDC, ERROR, <system-name>,
ki_gd_register_action failed with rc =<ret val>.
Probable Cause
Indicates an internal error.
Recommended
For a bladed system, execute the slotPowerOff command and slotPowerOn commands on the
Action
blade to recover the system. For a non-bladed system, execute the fastBoot command on the
switch to recover the system.
Severity
ERROR

CHS-1003

Message
<timestamp>, [CHS-1003], <sequence-number>,, ERROR, <system-name>, Slot ENABLED
but Not Ready during recovery, disabling slot = <slot number> rval =
value>.
Probable Cause
Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
Action
command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch.
Severity
ERROR

CHS-1004

Message
<timestamp>, [CHS-1004], <sequence-number>,, ERROR, <system-name>, Blade attach
failed during recovery, disabling slot = <slot number>, rval = <return value>.
Probable Cause
Indicates that a blade has failed during failover or recovery.
Recommended
On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn
Action
command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900,
5000, 7500, or AP7600 switch, reboot or power cycle the switch.
Severity
ERROR
Fabric OS Message Reference
53-1002448-01
Chapter
17
<return
123

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade 8/12cBrocade 8/24cFabric os v7.0.1

Table of Contents