Cdr-1001; Cdr-1002; Cdr-1003; Cdr System Messages - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

CDR System Messages

CDR-1001

Message
<timestamp>, [CDR-1001], <sequence-number>,, ERROR, <system-name>, Port<port
number> port fault. Please change the SFP or check cable.
Probable Cause
Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, a faulty cable
between peer ports, or that the port speed configuration does not match the capability of the SFP.
Recommended
Ensure that you are using compatible SFPs on the peer ports.
Action
Verify whether the SFPs have not deteriorated and the Fibre Channel cable is not faulty. Replace
the SFPs or cable, if necessary.
Severity
ERROR

CDR-1002

Message
<timestamp>, [CDR-1002], <sequence-number>, FFDC, ERROR, <system-name>, Port
<port number> chip faulted due to internal error.
Probable Cause
Indicates an internal error.
Recommended
For a bladed system, execute the slotPowerOff and slotPowerOn commands on the blade to recover
Action
the system. For a non-bladed system, perform fastBoot command on the switch to recover the
system.
Severity
ERROR

CDR-1003

Message
<timestamp>, [CDR-1003], <sequence-number>,, WARNING, <system-name>, S<slot
number>, C<chip index>: HW ASIC Chip error type = 0x<chip error type>. If the
problem persists, blade may need to be reset or replaced.
Probable Cause
Indicates an internal error in the Application Specific Integrated Circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Whenever this error occurs, restart the system at the next maintenance window. If the problem
Action
persists, replace the blade.
Severity
WARNING