Sulb-1022; Sulb-1023; Sulb-1024 - Brocade Communications Systems SN3000B Reference

Message reference
Hide thumbs Also See for SN3000B:
Table of Contents

Advertisement

SULB-1022

Message
<timestamp>, [SULB-1022], <sequence-number>,, WARNING, <system-name>, The blade
in slot <Slot number> has rebooted successfully with new firmware.
Probable Cause
Indicates that the blade in the specified slot has rebooted with new firmware. This is a normal step
in the firmwareDownload process.
Recommended
Run the firmwareDownloadStatus command to monitor the firmwareDownload progress.
Action
Severity
WARNING

SULB-1023

Message
<timestamp>, [SULB-1023], WARNING, <system-name>, The blade in slot <Slot number>
has rebooted during firmwaredownload.
Probable Cause
Indicates there may be an error caused by an unexpected disruption of the firmwareDownload
command, for example, by powering off and on of the indicated BP blade in the middle of a
firmwareDownload. The error may also be caused by persistent storage hardware failure or by a
software error.
Recommended
The firmwareCommit will be started automatically after the blade boots up to repair the secondary
Action
partition. If at the end of firmwareCommit, the blade firmware version is still inconsistent with the
active CP firmware, firmwareDownload will automatically be restarted on the blade. Run the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.
Severity
WARNING

SULB-1024

Message
<timestamp>, [SULB-1024], WARNING, <system-name>, Firmware commit has completed
on the blade in slot <Slot number>.
Probable Cause
Indicates the firmwareCommit operation has completed on the specified blade.
Recommended
Run the firmwareShow command to verify the firmware versions. If the blade firmware is the same
Action
as the active CP firmware, firmwareDownload has completed successfully on the blade. However, if
the firmwareCommit operation has been started to repair the secondary partition, at the end of
firmwareCommit, the blade firmware version may still be inconsistent with the active CP firmware.
In that case, firmwareDownload will automatically be restarted on the blade. Run the
firmwareDownloadStatus command to monitor the progress.
Severity
WARNING
Fabric OS Message Reference
53-1002448-01
101
SULB-1022
701

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brocade 8/12cBrocade 8/24cFabric os v7.0.1

Table of Contents