12
C3-1006
C3-1006
Message
<timestamp>, [C3-1006], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: Various non critical hardware errors were observed:
fault1:0x<fault1_cnt>, fault2:0x<fault2_cnt> thresh1:0x<threshold_used>.
Probable Cause
Indicates some errors found in hardware that may or may not impact data traffic.
Recommended
No action is required.
Action
Severity
WARNING
C3-1007
Message
<timestamp>, [C3-1007], <sequence-number>,, WARNING, <system-name>, S<slot
number>,P<port number>(<blade port number>): best effort QOS will be turned off at
next port state change as it is not supported under this configuration.
Probable Cause
Indicates that Quality of Service (QoS) will be turned off automatically at next port state change
since best effort is no longer supported on 4G or 8G platform long distance ports.
Recommended
No action is required.
Action
Severity
WARNING
C3-1008
Message
<timestamp>, [C3-1008], <sequence-number>,, WARNING, <system-name>, S<slot
number>,P<port number>(<blade port number>): QoS overwrites portcfglongdistance
vc_translation_link_init. ARB will be used on the link.
Probable Cause
Indicates that QoS overwrites the portcfglongdistance vc_translation_link_init 0 choice. ARB will be
used on the link.
Recommended
No action is required.
Action
Severity
WARNING
C3-1009
Message
<timestamp>, [C3-1009], <sequence-number>,, WARNING, <system-name>, S<slot
number>,P<port number>(<blade port number>): portcfglongdistance
vc_translation_link_init = 1 overwrites fill word IDLE. ARB will be used on the
link.
Probable Cause
Indicates that portcfglongdistance vc_translation_link_init 1 overwrites fill word IDLE. ARB will be
used on the link.
104
Fabric OS Message Reference
53-1002448-01